Non-invasive sphygmomanometers-Part 5: Requirements for the repeatability and reproducibility of NIBP simulators for testing of automated non-invasive sphygmomanometers

$48.00 $96.00 -50%
Product Code: ISO TS 81060-5
Stock In Stock
Edition: 1ST
Published: 02/2020
Number of Pages: 18
File Size: 1 file, 1 Byte

Available Options

Product Description

Non-invasive sphygmomanometers — Part 5: Requirements for the repeatability and reproducibility of NIBP simulators for testing of automated non-invasive sphygmomanometers

Introduction: The repeatability and reproducibility of NIBP simulators intended to test automated sphygmomanometers should be ensured, as they are often used to check the stability of an automated sphygmomanometer over time of use, after repair or to compare automated sphygmomanometers of the same type. This document should be used to determine the quality of the NIBP simulator once it is produced, sold or received by the responsible organization and thereafter periodically tested for the purpose of quality control. It specifies acceptance limits for repeatability and reproducibility regarding the amplitude and shape of the generated oscillations. Indirectly, it also tests the repeatability and reproducibility of the shape of the envelope of generated oscillations over (cuff) pressure, since the document specifies measurements at different static pressures at the same setting of the NIBP simulator, thus measuring the envelope at 2 or 3 pressure values. If there are reasons to doubt that this number is too low, the test might be extended to 5 or more static pressures. It is not practically hard to do, to compare the whole envelope of the generated oscillations by a dynamic process, i.e. by recording the data during the deflation or inflation of the cuff. This kind of dynamic measurement would require an identical deflation or inflation curve. Technically, this can be done by a closed-loop process, which is not a simple task. Since the oscillations at constant pressures are not different fro

Scope: This document specifies requirements for the repeatability and reproducibility of non-invasive blood pressure (NIBP) simulators intended to test automated sphygmomanometers utilizing the oscillometric non-continuous method only. In addition, the pulse rate set on the NIBP simulator is tested. This document is not intended to relate the signals, generated by the NIBP simulator, to the oscillometric signal recorded in a cuff attached to a human. It does not intend to test the interaction between the NIBP simulator and the tested automated sphygmomanometer (e.g. the agreement of the set values of the NIBP simulator and the displayed values of the tested automated sphygmomanometer or the properties of the cuff and tubing, such as design or elastic properties). NOTE 1 These parameters can be tested separately in a clinical investigation or by using different special test setups. This document does not check whether or not the NIBP simulator is able to test the accuracy of the absolute blood pressure value of oscillometric automated sphygmomanometers. NOTE 2 Usually this is tested by a clinical investigation according ISO 81060-2 or other protocols. This document is applicable to NIBP simulators testing automated sphygmomanometers for adults, children and neonates at the upper arm, thigh etc. and automated sphygmomanometers measuring at the wrist.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO TS 81060-5-2020 PDF

ISO TS 81060-5-2020 PDF

$48.00 $96.00