UL 486C-2023 PDF

UL 486C-2023 PDF

UL Standard for Safety Splicing Wire Connectors

$358.00 $716.00 -50%
Product Code: UL 486C
Stock In Stock
Edition: 8.
Published: 06/30/2023
Number of Pages: 75
File Size: 1 file, 910 KB

Available Options

Product Description

SAME AS CSA C22.2 NO 188 This Standard applies to single-polarity, hand-, or tool-applied splicing wire and cable connectors intended for use with all alloys of copper, aluminum conductors, or copper-clad aluminum conductors, or all three, in accordance with the Canadian Electrical Code Part I, CSA C22.1, in Canada, the National Electrical Code, NFPA-70, in the United States of America, or the Standard for Electrical Installations, NOM-001-SEDE, in Mexico, as follows: Note: Copper-clad aluminum conductors are for use only in the United States in accordance with the National Electrical Code, NFPA 70. a) Connectors intended to hold two or more conductor(s); b) Connectors intended for use in appliances and equipment that comply with the requirements for such appliances and equipment; c) Connectors intended for use with 6 AWG (13.3 mm 2 ) or smaller conductors; d) Uninsulated connectors that are used in circuits rated 8 000 V and less; e) Connectors intended for use in air-handling spaces; f) Exothermically welded wire connectors; and g) Splices and taps installed on service conductors. Note: Examples of splicing wire connectors include twist-on connectors, insulation-piercing or displacement connectors, springaction connectors, tool-applied crimp, mechanical set-screw connectors, etc. This Standard is intended for splicing wire connectors suitable for use with conductors in the size ranges as follows: a) Aluminum: 1) 12 AWG (3.3 mm 2 ) and 10 AWG (5.3 mm 2 ) solid; 2) 12 AWG (3.3 mm 2 ) to 6 AWG (13.3 mm 2 ) stranded, Class B concentric, compressed, and compact; and 3) 12 AWG (3.3 mm 2 ) to 6 AWG (13.3 mm 2 ) stranded single input wire (SIW). In Mexico, the use of aluminum conductors is permitted only with thermoset insulation and for sizes of 6 AWG (13.3 mm 2 ) and higher. b) Copper-clad aluminum: 1) In Canada, this construction is not allowed. 2) In Mexico, this construction is not allowed. 3) In the United States: i) 12 AWG (3.3 mm 2 ) and 10 AWG (5.3 mm 2 ) solid; and ii) 12 AWG (3.3 mm 2 ) to 6 AWG (13.3 mm 2 ) stranded, Class B concentric, compressed, and Class C concentric. c) Copper: 1) 30 AWG (0.05 mm 2 ) to 10 AWG (5.3 mm 2 ) solid; and 2) 30 AWG (0.05 mm 2 ) to 6 AWG (13.3 mm 2 ) stranded, Class B concentric and compressed, and Class C concentric. d) Compact-stranded copper conductors: In Canada and Mexico, for 8 AWG (8.4 mm 2 ) and 6 AWG (13.3 mm 2 ). In the United States this is not applicable. e) Rigid (solid and stranded) metric wire sizes, Classes 1, 2, 5, and 6, in the range of 0.5 – 10 mm 2 , in addition to AWG sizes, with AWG ratings mandatory and metric wire ratings optional. Note 1: Metric wire sizes are based on the IEC Standard for Conductors of Insulated Cables, IEC 60228. Note 2: For example, a connector rated for 6 AWG (13.3 mm 2 ) – 14 AWG (2.1 mm 2 ) may be additionally rated for 10 – 2.5 mm2. See Annex C for example. f) Other class and strand configurations as indicated by marking. This Standard is intended for splicing wire connectors suitable for currents not exceeding the ampacity of insulated conductors rated 75 °C or 90 °C, in accordance with the rating of the connector. This Standard does not apply to: a) Insulated splicing wire connectors intended for use at voltage levels in excess of 2 000; b) Terminal wire connectors; c) Wire binding screw terminals; d) Built-in terminal connectors on devices rated less than 30 A and intended for outlet box mounting or having provision for stress relief; e) Built-in terminal connectors on devices having integral cable clamps; f) Flat quick connect terminals; and g) Soldering lugs.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
UL 486C-2023 PDF

UL 486C-2023 PDF

$358.00 $716.00