UL 61010-2-040-2021 PDF
UL Standard for Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use – Part 2-040: Particular Requirements for Sterilizers and Washer-Disinfectors Used to Treat Medical Materials
- AA-The Aluminum Association
- AAMI-Association for the Advancement of Medical Instrumentation
- AASHTO-American Association of State Highway and Transportation Officials
- AATCC-American Association of Textile Chemists and Colorists
- ACI-American Concrete Institute
- ANSI-American National Standards Institute
- API-American Petroleum Institute
- AS-Standards Australia
- ASABE-American Society of Agricultural and Biological Engineers (Formerly ASAE)
- ASCE-American Society of Civil Engineers
- ASHRAE-American Society of Heating, Refrigerating, and Air Conditioning Engineers
- ASME-ASME International
- ASTM-ASTM International
- AWS-American Welding Society
- AWWA-American Water Works Association
- BS-BSI Group
- ISO-International Organization for Standardization
- RTCA-RTCA, Inc.
- IEC-International Electrotechnical Commission
- IEEE-Institute of Electrical and Electronics Engineers
- SAE-SAE International
- UL-Underwriters Laboratories
- ULC-Underwriters Laboratories of Canada
- UNE-Asociación Española de Normalización
Your shopping cart is empty!
Product Description
SAME AS IEC 61010-2-040 This group safety publication is primarily intended to be used as a product safety standard for the products mentioned in the scope, but shall also be used by technical committees in the preparation of their publications for products similar to those mentioned in the scope of this standard, in accordance with the principles laid down in IEC Guide 104 and ISO/IEC Guide 51. Equipment included in scope This part of IEC 61010 specifies safety requirements for electrical equipment intended for sterilization, washing, and disinfection of medical materials in the medical, veterinary, pharmaceutical and laboratory fields, when used under the environmental conditions of Examples of such equipment include the following: a) STERILIZERS and disinfectors using steam and/or hot water as the sterilant; b) STERILIZERS and disinfectors using toxic gas, toxic aerosol or toxic vapour as the sterilant; c) STERILIZERS and disinfectors using hot air or hot inert gas as the sterilant; and d) WASHER-DISINFECTORS. Equipment excluded from scope This standard does not apply to equipment within the scope of: a) IEC 60065 (Audio, video and similar electronic apparatus); b) IEC 60204 (Safety of machinery – Electrical equipment of machines); c) IEC 60335 (Household and similar electrical appliances); d) IEC 60364 (Electrical installations of buildings); e) IEC 60439 (Low-voltage switchgear and controlgear assemblies); f) IEC 60601 (Medical electrical equipment); NOTE IEC 60601-1:2005, 3.63, defines "medical electrical equipment" as follows (notes to entry are omitted): Electrical equipment, having an applied part or transferring energy to or from the patient or detecting such energy transfer to or from the patient and which is: a) provided with not more than one connection to a particular supply MAINS; and b) intended by its manufacturer to be used: 1) in the diagnosis, treatment, or monitoring of a patient; or 2) for compensation or alleviation of disease, injury or disability. g) IEC 60950 (Information technology equipment including electrical business equipment, except as specified in 1.1.3); h) IEC 61558 (Power transformers, power supply units and similar); i) IEC 61010-031 (Hand-held probe assemblies); j) IEC 61243-3 (Live working – Voltage detectors – Part 3: Two-pole low-voltage type). This document does not apply to the following types of equipment: aa) equipment for use in hazardous atmospheres (see IEC 60079); however this document does apply to an atmosphere created inside equipment by a flammable sterilizing agent (see 13.2.101 and 13.2.102); bb) laboratory equipment for the heating of materials for purposes other than sterilization or disinfection (see IEC 61010-2-010); cc) laundry equipment (see IEC 60335-2-4, IEC 60335-2-7, IEC 60335-2-11, and ISO 10472 (all parts)), unless designed for disinfecting medical materials; dd) dishwashers (see IEC 60335-2-5 and IEC 60335-2-58). Computing equipment This standard applies only to computers, processors, etc. which form part of equipment within the scope of this standard or are designed for use exclusively with the equipment. NOTE Computing devices and similar equipment within the scope of IEC 60950 and conforming to its requirements are considered to be suitable for use with equipment within the scope of this standard. However, some of the requirements of IEC 60950 for resistance to moisture and liquids are less stringent than those in this standard (see 5.4.4 second paragraph)). Object Aspects included in scope The purpose of the requirements of this standard is to ensure that HAZARDS to the OPERATOR and the surrounding area are reduced to a tolerable level. Requirements for protection against particular types of HAZARD are given in Clauses 6 to 13, as follows: a) electric shock or burn (see Clause 6); b) mechanical HAZARDS (see Clauses 7 and 8); c) spread of fire from the equipment (see Clause 9); d) excessive temperature (see Clause 10); e) effects of fluids and fluid pressure (see Clause 11); f) effects of radiation, including lasers sources, and sonic and ultrasonic pressure (see Clause 12); g) liberated gases (including the non-intentional escape of toxic gas), pathogenic substances, explosion and implosion (see Clause 13). Requirements for protection against HAZARDS arising from REASONABLY FORESEEABLE MISUSE and ergonomic factors are specified in Clause 16. RISK assessment for HAZARDS or environments not fully covered above is specified in Clause 17. NOTE Attention is drawn to the existence of additional requirements regarding the health and safety of labour forces. Aspects excluded from scope This standard does not cover: a) reliable function, performance, or other properties of the equipment not related to safety; b) effectiveness of transport packaging; c) EMC requirements (see the IEC 61326 series); d) protective measures for explosive atmospheres (see the IEC 60079 series). aa) special requirements for protection against chemical and high-risk micro-biological HAZARDS associated with the LOAD; bb) general requirements for the design of calorifiers, shell boilers and PRESSURE VESSELS. NOTE National and other regulations or codes apply for the safety of calorifiers, shell boilers and PRESSURE VESSELS (see 14.101). Verification This standard also specifies methods of verifying that the equipment meets the requirements of this standard, through inspection, TYPE TESTS, ROUTINE TESTS, and RISK assessment. Environmental conditions Normal environmental conditions This standard applies to equipment designed to be safe at least under the following conditions: a) indoor use; b) altitude up to 2 000 m; c) temperature 5 °C to 40 °C; d) maximum relative humidity 80 % for temperatures up to 31 °C decreasing linearly to 50 % relative humidity at 40 °C; e) MAINS supply voltage fluctuations up to ±10 % of the nominal voltage; f) TRANSIENT OVERVOLTAGES up to the levels of OVERVOLTAGE CATEGORY ll; NOTE 1 These levels of transient overvoltage are typical for equipment supplied from the building wiring. g) TEMPORARY OVERVOLTAGES occurring on the MAINS supply. h) applicable POLLUTION DEGREE of the intended environment (POLLUTION DEGREE 2 in most cases). NOTE 2 Manufacturers may specify more restricted environmental conditions for operation; nevertheless the equipment must be safe within these normal environmental conditions. Extended environmental conditions This standard applies to equipment designed to be safe not only in the environmental conditions specified in 1.4.1, but also in any of the following conditions as RATED by the manufacturer of the equipment: a) outdoor use; b) altitude above 2 000 m; c) ambient temperatures below 5 °C or above 40 °C; d) relative humidity above the levels specified in 1.4.1; e) MAINS supply voltage fluctuations exceeding ±10 % of the nominal voltage; f) WET LOCATION; g) TRANSIENT OVERVOLTAGES up to the levels of OVERVOLTAGE CATEGORY III or IV (see Annex K).