UL 61010A-2-020-2002 PDF

UL 61010A-2-020-2002 PDF

UL Standard for Safety Electrical Equipment for Laboratory Use; Part 2: Particular Requirements for Laboratory Centrifuges

$92.50 $185.00 -50%
Product Code: UL 61010A-2-020
Stock In Stock
Edition: 1
Published: 09/16/2002
Number of Pages: 42
File Size: 1 file, 110 KB

Available Options

Product Description

W/D S/S BY UL 61010-1 This Part 2 is applicable to electrically powered LABORATORY CENTRIFUGES. Aspects excluded from scope This Part 1 of the standard does not cover: - reliable function, performance or other properties of the equipment; - effectiveness of transport and packaging; - servicing (repair); - protection of servicing (repair) personnel. NOTE - Servicing personnel are expected to be reasonably careful in dealing with obvious hazards, but the design should protect against mishap by the use of warning labels, shields for hazardous voltage TERMINALS, segregation of low-voltage circuits from hazardous voltages, etc. More important, servicing personnel should be trained against unexpected hazards. - additional precautions which may need to be observed when centrifuging materials which are flammable or explosive (see 5.4.4.101); - additional precautions which may need to be observed when centrifuging materials that chemically react vigorously (see 5.4.4.101). - additional precautions related to safety hazards arising from leaking BIOSEALS and other biosafety components. Equipment excluded from scope This Part 1 does not apply to: - electric power equipment, for example power electronics; - machine TOOLS and their controls (see IEC 204); - Class 0, 5, 1 and 2 alternating current watt-hour meters (see IEC 521); - medical electrical equipment within the scope of IEC 601; - biological amplifies which link humans to equipment in research or teaching contexts; - TYPE-TESTED and partially TYPE-TESTED assemblies of low-voltage switchgear and controlgear (see IEC 439-1); - circuits and equipment which are part of the building electrical installation (see IEC 364); - computers, processors and similar equipment, except as specified in 1.1.3 (see IEC 950); - transformers separate from the equipment (see IEC 742); - equipment intended for household use (see IEC 335); - equipment intended for use in explosive gas atmospheres (see IEC 79). - rotating electrical machinery within the scope of IEC 34; - CENTRIFUGES (used with materials that are toxic, radioactive, or contaminated with pathogenic micro-organisms). - BIOSEALS and other biosafety components.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
UL 61010A-2-020-2002 PDF

UL 61010A-2-020-2002 PDF

$92.50 $185.00