UL Standard for Safety Transfer Switch Equipment, Meter-Mounted

$201.00 $402.00 -50%
Product Code: UL CAN/UL 1008M
Stock In Stock
Edition: 1.
Published: 04/03/2024
Number of Pages: 34
File Size: 1 file, 450 KB

Available Options

Product Description

These requirements cover automatic and non-automatic (manual) transfer switch equipment, operating at 600 Vac or less and 200 A or less meter-mounting device, intended for insertion into the jaws of the meter socket of a and used in non-hazardous locations in accordance with the National Electrical Code (NEC), NFPA 70, and the Canadian Electrical Code, Part I, CSA C22.1. NOTE: In the United States, the term meter-mounting device refers to an enclosed meter socket. These devices are intended for use in other than life safety systems. In the United States, these are intended for use in optional standby systems only and are not intended for use in Emergency or Legally Required Standby Systems (Life Safety Systems). In Canada, these devices are for use in applications where loss of power is not considered safety critical. These devices are intended for one of the following applications: a) Permanent connection of a stationary generator to power a premise wiring system, where the generator is connected as a non-separately derived system, where the neutral (grounded circuit conductor) of the generator is not bonded to ground or the generator frame; or b) Cord connection of a portable generator to power a premises wiring system, where the neutral (grounded circuit conductor) of the generator is not bonded to ground or the generator frame, and bonding of the neutral (grounded circuit conductor) to ground will occur: 1) In the United States, within the meter socket, or 2) In Canada, at the meter base or service box. Note 1: In Canada, metering equipment may be connected on the supply side of the service box in some instances as outlined in the Canadian Electrical Code, Part I, Rule 6-402 (2). In the United States, installation of meter mounted transfer switches on the line side of the service disconnect is permitted by Section 230.82 of the National Electrical Code, NFPA 70. Note 2: In Canada, emergency systems are identified as emergency power supplies. In the United States, this does not apply. When these devices are connected between the meter mounting socket and the electric utility (supply authority) meter, and installed on the line side of the service disconnect, approval by the serving utility may be required before installation. These requirements only cover transfer switches which are completely enclosed and have no accessible energized parts when installed in a meter socket in conjunction with the electrical utility meter. Transfer switches are rated in amperes and are considered to be acceptable for total system transfer, which includes control of motors, electric-heating loads, and transformer loads.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
UL CAN/UL 1008M-2024 PDF

UL CAN/UL 1008M-2024 PDF

$201.00 $402.00