UL RP 60079-46-2022 PDF

UL RP 60079-46-2022 PDF

UL Standard for Saftey Recommended Practice for Explosive Atmospheres – Part 46: Equipment Assemblies

$100.00 $200.00 -50%
Product Code: UL RP 60079-46
Stock In Stock
Edition: 1
Published: 07/22/2022
Number of Pages: 39
File Size: 1 file, 330 KB

Available Options

Product Description

1DV.1 DE Modification of first 2 paragraphs of Clause 1 to replace with the following: 1DV.1.1 This document, which is a Recommended Practice, specifies requirements for the design, construction, assembly, testing, inspection, marking, documenting and assessment of equipment assemblies for use in explosive atmospheres under the responsibility of the assembly manufacturer (see 3.4.2ADV) 1DV.1.2 The requirements of this document apply to individual items according to the UL 60079 series or UL 80079 series that comprise the assembly and that have individual certificates. These individual items are then integrated as part of the equipment assembly. Also included are requirements to address aspects for the assembly which may be beyond the certificates of the individual items forming the assembly. The scope of this document includes assessment of the additional requirements for assemblies for hazardous areas and does not include requirements for non-hazardous areas. It is assumed that compliance with other electrical or mechanical requirements that are applicable for non-hazardous areas will be verified by either the same or different party in addition to the requirements of this document. 1DV.2 DR Modification of 3rd through 5th paragraphs, including Notes, of Clause 1 to replace with the following: 1DV.2.1 This document does not apply to: – equipment which is covered, in its entirety, by one or more UL 60079 and UL 80079 equipment types of protection; – pressurized rooms, “p”, and artificially ventilated rooms, “v” in accordance with UL 60079-13, pressurized rooms in accordance with NFPA 496, and other standards addressing specific Ex assemblies; – installation at the end-user site under the scope of the applicable installation codes (e.g. NFPA 70, API RP 14F, API RP 14FZ); – classification of the hazardous area; – equipment assemblies for mines susceptible to firedamp (Group I applications); – inherently explosive situations and dust from explosives or pyrophoric substances (for example explosives manufacturing and processing); – rooms used for medical purposes; – electrical installations in areas where the hazard is due to flammable mist. 1DV.2.2 This document is only intended to provide validation for the equipment assembly as provided. Any subsequent changes made after installation are not covered by this document, and are the responsibility of the local authority having jurisdiction over the installation . NOTE 1 Additional guidance on the requirements for hazards due to hybrid mixtures of dust or flyings and flammable gas or vapour is provided in NFPA 70. 1DV.2.3 Where a requirement of this document conflicts with a requirement of either UL 60079-0 or UL 80079-36, the requirement of this document takes precedence. NOTE 2 For this first edition, the only requirements of this document that take precedence over UL 60079-0 or UL 80079-36 are the markings for equipment assemblies. 1ADV.3 DE Modification to add to Clause 1: Where references are made to IEC and ISO standards, the referenced requirements found in these standards shall apply as modified by any applicable US National Differences for the standard (see Clause 2).

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
UL RP 60079-46-2022 PDF

UL RP 60079-46-2022 PDF

$100.00 $200.00